Oxygen Gas Turbine Flow Meter (LWGQ Series)
Custody-Grade Billing for Medical Gas, Industrial-Gas Delivery, and Furnace Enrichment
Accuracy ±0.5 / 1.0 / 1.5 % of rate options
Pipe DN50 to DN150
Turndown up to 1:30 (top G-class)
- Oil-free 316L build standard. ASTM G93 / ISO 15001 oxygen-cleanliness certificate is buyer-arranged with a notified body.
- T+P (temperature and pressure) compensation built-in; corrected Nm³ (normal cubic meters) on the 4-20 mA loop
- Ex d (flameproof) II CT6 Gb + Ex ia (intrinsically safe) II CT6 Ga dual hazardous-area

LWGQ oxygen turbine for custody-grade volumetric billing on medical-gas distribution, industrial-gas vendor delivery, and steel + glass furnace enrichment. 316L body with factory oil-free build (specified at quote; buyer arranges ASTM G93 / ISO 15001 certification with a notified body). T+P compensation outputs corrected volume on the 4-20 mA loop. 1:30 turndown captures off-peak draw; dual Ex d + Ex ia covers general and classified zones.
Benefits
- Custody-grade ±0.5 % of rate: factory K-factor for fair internal cost-allocation and vendor-to-customer billing.
- Oil-free build for O₂ service: factory degreasing of wetted parts (specified at quote); buyer arranges ISO 15001 cert with notified body.
- 316L wetted parts: corrosion-resistant for medical-gas distribution and industrial pure-oxygen service.
- T+P compensation built-in: corrected Nm³ on the 4-20 mA loop, no external multivariable.
- Dual hazardous-area: Ex d II CT6 Gb + Ex ia II CT6 Ga for general and classified zones.
- Multi-output: pulse, 4-20 mA, RS-485 Modbus, HART, GPRS / 4G for SCADA and remote billing.
- Lead time 5–7 business days from the factory.
Typical applications
Four oxygen applications where LWGQ is the custody-grade volumetric pick.
Hospital O₂ manifold sub-measurement
Bulk O₂ tank to ward manifold distribution. Per-ward billing for cost-allocation; oil-free 316L build for medical-grade service.
Industrial-gas vendor fence billing
Vaporizer outlet to customer fence, gaseous phase. The bulk-gas vendor invoices on Nm³ delivered; ±0.5 % of rate is the contract basis.
Steel-EAF oxygen enrichment
O₂ lance and side-wall injection on the electric-arc furnace. Per-heat cost allocation, per-ton accounting; Ex d for melt-shop service.
Glass-furnace oxy-fuel combustion
Oxy-fuel burner feed on container and float-glass tanks. Cost tracking per pull, NOx and fuel savings audit basis.
Specifications
| Measurement principle | Velocity-type turbine with magnetic-pickup pulse output |
|---|---|
| Pipe size range | DN50 – DN150 (2″ – 6″) standard for oxygen build; DN25 – DN300 family |
| Accuracy | ±0.5 % of rate / ±1.0 % of rate / ±1.5 % of rate (factory K-factor calibration with each meter) |
| Turndown | 1:10 to 1:30 (depending on G-class flow rating selection) |
| Working pressure | 1.6 / 2.5 / 4.0 / 6.3 / 10 MPa metric, ANSI 150 LB / 300 LB / 600 LB |
| Medium temperature | −25 to +80 °C (gaseous oxygen above the vaporizer only; NOT cryogenic LOX) |
| Ambient range | −20 to +65 °C, 5 % to 90 % RH non-condensing, 86 to 106 kPa atmospheric |
| Body material | 316L stainless steel, factory oil-free build for oxygen service (specified at quote) |
| Sensor material | 316L |
| O₂-clean preparation | Factory degreasing per ASTM G93 method; buyer arranges ISO 15001 third-party certification with a notified body if required |
| Compensation | None / temperature / pressure (T+P standard for billing) |
| Output signals | Pulse 3-wire, 4-20 mA 2-wire / 3-wire, RS-485 Modbus RTU, HART, GPRS / 4G IoT |
| Power supply | 24 V DC standard, 3.6 V lithium battery option for off-grid metering |
| Display | Instantaneous flow, cumulative volume, temperature, pressure on integrated LCD |
| Data logging | Daily log + timed-interval log (audit-trail retrievable) |
| Transmission distance | Pulse 3-wire ≤ 300 m, 4-20 mA 2-wire ≤ 1500 m (load ≤ 500 Ω), RS-485 / HART ≤ 1200 m |
| Ingress protection | IP65 / IP66 |
| Hazardous area | Ex d II CT6 Gb (flameproof) + Ex ia II CT6 Ga (intrinsically safe) |
| Approvals | EMC 2014/30/EU (Annex II), ISO 9001 calibration certificate with each meter |
Installation
Five install rules for the LWGQ oxygen turbine.
- Maintain oxygen-clean handling from receipt through install The factory ships the meter degreased and bagged. Do not break the bag until install; do not contaminate gaskets, bolts, or mating flanges with hydrocarbon grease. Use only oxygen-service-rated thread sealant on flange bolts.
- Filter and isolation valves upstream and downstream Install a gas filter upstream of the meter and isolation valves on both sides for service maintenance. Never connect the filter directly to the meter inlet flange; debris damages the rotor bearing and shifts the K-factor.
- Horizontal install with the housing arrow aligned to flow The LWGQ supports horizontal install only; vertical mount is not permitted. The flow direction arrow on the housing must match line flow.
- Maintain ≥ 3 DN upstream and ≥ 1 DN downstream straight pipe The integrated upstream flow conditioner accepts the 3 DN minimum upstream of any elbow or valve, and 1 DN minimum downstream. Tighter installations distort the velocity profile and bias the K-factor low.
- Earth-ground the housing on a separate ground line External-power builds require reliable earth grounding, but the meter ground must NOT share with the high-voltage system. During pipe work never bond welding-system ground to the meter ground; transient currents damage the pulse pickup.
Frequently asked questions
Need help sizing an oxygen custody build?
Send line size, P/T, O₂ purity, cleanliness level, cert need. Reply in 1 day; lead time 5–7 business days.