Natural Gas Ultrasonic Flow Meter
Mid-Grade Transit-Time Metering for Industrial-Park Gas
Accuracy ±1.0 % / ±1.5 % of rate
DN25 to DN200 inline flanged build, single-path or dual-path
1:100 turndown standard, 1:160 by order
- Near-zero pressure drop; no obstruction in the bore, no rotor, no bluff body
- Bidirectional readback for reverse-flow or load-balancing service on industrial-park feeders
- Ex d IIC T6 Gb flameproof + IP65 + 24 V DC or 3.6 V lithium battery for Automated Meter Reading (AMR)
Transit-time gas flow measurement for industrial-park mains, fuel-gas-to-boiler headers, town-gas regulator-station accounting, and wholesale-billing aggregation between regulator and downstream meters. Mid-grade ±1.0 % to ±1.5 % of rate on DN25 to DN200, 1.6 MPa ceiling, single-path or dual-path. In-scope service: clean dry natural gas, town gas, fuel gas, or compressed air post-dryer. Out-of-scope service (wet / 2-phase / cryogenic LNG / raw biogas) goes to the swirl, vortex, or Coriolis family per medium.
Benefits
- Near-zero pressure drop: no obstruction in the bore. Industrial-park feeders running low post-regulator pressure keep their head.
- 1:100 turndown standard, 1:160 by order: one meter covers off-peak / shoulder / peak diurnal swing on a distribution main.
- Bidirectional readback: handles reverse-flow and load-balancing service on industrial-park feeders without re-piping.
- No moving parts, no rotor wear: zero-wear electronics for clean dry gas service, no rotor service cost over the life cycle.
- Seven output options: pulse, 4-20 mA (2-wire or 3-wire), RS-485 Modbus, HART, 4G wireless for utility telemetry.
- Ex d IIC T6 Gb flameproof + IP65: classified industrial-park service with sealed housing.
- Lead time 5–7 business days from the factory.
Configure your build.
Select your specs and the configurator returns the CSUF model code plus a ballpark unit price. Submit for engineering review and verified sizing within 4 business hours.
Your Configuration
✓ Gas composition reviewed by application engineer
✓ Reply within 4 business hours
Typical applications
Four applications where mid-grade transit-time gas flow measurement wins on diurnal swing and zero rotor wear.
Industrial-park gas mains aggregator
DN100 to DN200 campus header feeding multiple tenants. 1:100 turndown captures shift swings. Mid-grade accuracy supports inter-tenant cost allocation.
Fuel-gas-to-boiler / CHP feed
DN80 to DN150 boiler-house header. Wide turndown holds part-load firing. Bidirectional readback covers transient cross-flow on tied combustion grids.
Town-gas regulator-station accounting
DN150 to DN200 wholesale-billing aggregator between regulator and downstream meters. Off-peak diurnal flow stays inside the 1:100 turndown range.
Distribution sub-station feeder accounting
Post-regulator low-ΔP distribution main 0.4 to 1.6 MPa. Near-zero pressure drop keeps line head; no rotor wear on diurnal cycling.
Specifications
| Measurement principle | Transit-time ultrasonic; paired crystals at oblique angle, Δt between downstream and upstream pulse proportional to mean axial velocity |
|---|---|
| Path count | Single-path (1) or dual-path (2) |
| Pipe size range | DN25, DN50, DN80, DN100, DN150, DN200 (six sizes) |
| Flow range (air reference) | DN25: 0.4 to 40 m³/h · DN50: 1.6 to 160 · DN80: 4.0 to 400 · DN100: 6.5 to 650 · DN150: 16 to 1,600 · DN200: 25 to 2,500 m³/h |
| Accuracy | ±1.0 % of rate (class A) or ±1.5 % of rate (class B); headline figure applies above the transition flow Qt = 0.1 × Qmax |
| Accuracy spec (per range) | Class A: ±1.0 % of rate from Qt to Qmax · Class B: ±1.5 % of rate from Qt to Qmax · Below Qt (Qmin ≤ Q < Qt) accuracy widens to ±2 % of rate for both classes. Qt = 0.1 × Qmax by default; 0.0625 × Qmax on the 1:160 special-order turndown build. |
| Repeatability | ±0.1 % |
| Turndown | 1:100 standard; 1:160 by order (specify at order) |
| Working pressure | Up to 1.6 MPa standard; extended pressure by quote |
| Medium temperature | −10 to +50 °C standard; −40 to +60 °C special |
| Ambient range | −20 to +60 °C, ≤ 95 % RH non-condensing |
| Spool material | Carbon steel / 304 stainless / 316 stainless / special (configurable) |
| Medium | Clean dry natural gas, town gas, fuel gas, post-upgrade biomethane, post-dryer compressed air |
| Service exclusions | Wet gas, condensate-bearing service, 2-phase, raw biogas, cryogenic, steam, pulsating service without accumulator |
| Compensation | None / temperature / pressure (selectable per Comp field in configurator) |
| Output signals | Pulse 3-wire, pulse + battery-card, 4-20 mA 3-wire / 2-wire, RS-485 Modbus RTU, HART, 4G wireless |
| Power supply | 24 V DC or 3.6 V lithium battery (battery suited for off-grid AMR endpoints) |
| Display | LCD; instantaneous flow, cumulative volume, temperature and pressure if compensated |
| Form factor | Integrated (1) / remote split (2) |
| Process connection | Flanged spool body, GB/T 9119-2010 compatible at PN1.6 |
| Ingress protection | IP65 |
| Hazardous area | Ex d IIC T6 Gb (flameproof) |
| Straight pipe | ≥ 10 D upstream, ≥ 5 D downstream from nearest disturbance |
| Approvals | EMC 2014/30/EU (Annex II), ISO 9001 calibration record with each meter |
| Lead time | 5–7 business days from factory |
Installation
Five install rules. Pre-condition: clean dry single-phase gas at the meter inlet.
- Straight pipe ≥ 10 D upstream and ≥ 5 D downstream Measured from the nearest fitting, elbow, valve, or branch on either side of the spool. The transit-time method reads mean axial velocity along the path; swirl and asymmetry inside the path bias the reading.
- Gas filter upstream of every meter A line-service gas filter must precede the meter. Particulate fouls the crystal faces and shifts zero. Place the filter outside the 10 D upstream run so it does not generate its own swirl into the spool.
- Pressure regulator upstream of the meter Distribution and industrial-park service needs a regulator upstream to stabilize inlet pressure within the meter range. Steady inlet pressure protects the path geometry and standard m³/h reporting through the T+P compensation channel.
- Avoid wet gas, 2-phase service, and condensate carry-over Liquid carry-over blocks the crystal face and distorts the acoustic path. If the line risks condensate during upset, fit a knockout pot upstream. Saturated and 2-phase service goes to the swirl-flow-meter (LUXB Series).
- Locate the meter at least 10 D from any pulsation source Compressors, blowers, and other pulsation sources degrade transit-time averaging. Mount the meter at least 10 D downstream of any such source, or fit an accumulator upstream if pulsation is unavoidable.