Insertion Vortex Flow Meter
Hot-Tap Insertion Vortex
Accuracy of ±1.5% of rate
Temperature service −45 to +250 °C
Turndown ratio of 1:30
- Line sizes DN80 to DN6000
- Hot-tap install with 1-1/2″ NPT or flanged isolation valve
- Body materials 316L stainless or Hastelloy C

The Insertion Vortex Flow Meter installs through a 1-1/2″ isolation valve on lines DN80 and larger, including hot-tap retrofits. Single-point velocity measurement converts to volumetric flow via pipe ID at calibration.
316L wetted parts cover most service. Hastelloy C is the upgrade for chloride or acid carry-over. The retraction mechanism allows servicing without process shutdown when the isolation valve is in place.
Benefits
- Hot-tap installation: probe seats through a 1″ or 2″ NPT boss + ball valve on the live pipe; zero shutdown.
- Pipe-size independent capital cost: one probe covers DN200–DN2000+; a DN600 insertion runs ~1/6 the cost of an equivalent in-line vortex.
- Retractable version: compression packing gland + safety chain pulls the probe under pressure for duty/standby rotation or cleaning.
- Reading accuracy: ±1.5 %, 1:10 turndown, sampled at the Chebyshev 1/8-ID point; sub-measurement, allocation, trend monitoring.
- Sensor pedigree: bluff body and piezo sensor shared with LUGB-VRd (2024 China Instrument Society Top-10 New Product).
- Hazardous-area certification: CNEX Ex d IIC T6 Gb (flameproof, Zone 1) optional.
- Lead time: 5–7 business days from factory with ISO 9001 calibration cert.
Insertion vs in-line at scale
At DN400 and above, the math stops being close. Indicative unit pricing excluding freight, install labour, and commissioning.
| Pipe size | In-line flanged vortex | Insertion vortex | Savings on meter alone |
|---|---|---|---|
| DN200 | $2,280 | $980 | ~55% less |
| DN300 | $3,180 | $980 | ~70% less |
| DN600 | $7,800 | $1,280 | ~85% less |
| DN1000 | $18,000+ | $1,580 | ~90% less |
| DN1500 | custom forging $25,000+ | $1,880 | Only viable option |
| DN2000 | not stocked | $2,380 | Only viable option |
Flanged in-line pricing skyrockets above DN400 because the flange pair, lifting rig, and shipping weight dominate. Insertion price stays nearly flat; the probe shaft is the only thing that lengthens. If you don’t need custody-transfer accuracy, insertion wins decisively above DN300.
Quick specifications.
| Measurement Principle | Karman vortex; point velocity multiplied by geometry K-factor |
|---|---|
| Pipe Size Coverage | DN200 – DN2000 on a single probe series (standard / long-shaft / extra-long-shaft) |
| Compatible Media | Compressed air · natural gas · steam (sat / superheat) · nitrogen · CO₂ · flue gas |
| Accuracy | ±1.5% of reading (velocity-profile traversed, Re > 20,000) |
| Installation | Hot-tap through 1″, 1.5″, or 2″ NPT boss or 300LB weld-o-let |
| Retractable Option | Fixed or retractable-under-pressure via ball valve + packing gland |
| Pressure | 1.6 – 4.0 MPa (fixed PN16–PN40) · 1.6 – 2.5 MPa (retractable PN16–PN25 gland rated) |
| Medium Temperature | -20 to +250 °C |
| Output Signal | 4–20 mA · Pulse · RS485 Modbus RTU |
| Hazardous Area | Ex d (CNEX flameproof) flameproof standard · Ex d (CNEX flameproof) optional |
Configure and add to cart.
Tell us your pipe ID and process conditions; we’ll generate the model code, pre-set the insertion depth, and quote a ballpark price. Engineering review within 4 business hours.
Your Configuration
✓ K-factor calibrated for your pipe ID
✓ Reply within 4 business hours
Insertion vortex in the field
Large Gas Transmission Lines
DN500–DN1500 gas where in-line is impractical. Sub-metering for allocation, not custody.
Compressed-Air Main Retrofits
DN200+ compressed-air ring mains without metering. Hot-tap one insertion per branch for department allocation; impossible in-line without cutting the ring.
Stack & Flue-Gas Monitoring
Boiler stack draft, flue-gas emissions reporting, combustion-air inlet. Rectangular ducts on request.
HVAC & District Energy
DN400–DN800 chilled-water / district-heating returns where in-line capital cost is out of budget. Load-balancing trend, not billing.
Specifications
Performance
| Accuracy of reading | ±1.5% (fully-developed turbulent profile) |
|---|---|
| Repeatability | ±0.3% |
| Velocity range | 3 – 80 m/s (gas) |
| Reynolds number range | Re > 20,000 at probe body |
| Turndown | Approximately 1:20 on reading |
| K-factor | Pre-programmed per your pipe ID input |
Process & Environment
| Pipe size coverage | DN200 – DN2000 (three shaft length options) |
|---|---|
| Pressure range | 0.1 – 4.0 MPa (fixed) · 0.1 – 2.5 MPa (retractable) |
| Medium temperature | -20 to +250 °C |
| Ambient temperature | -40 to +70 °C |
| Enclosure rating | IP66 / IP67 standard · Ex d (CNEX flameproof) |
| Process connection | 1″ / 1.5″ / 2″ NPT · 1.5″ 300LB flanged option |
Electrical & Output
| Power supply | 24 VDC (2-wire loop powered) |
|---|---|
| Analogue output | 4–20 mA, scaled to velocity or volumetric flow |
| Pulse output | Per-pulse volume at standard conditions |
| Digital output | RS485 Modbus RTU · HART optional |
| Local display | LCD · m/s, total volume, status |
| Modbus registers | Instantaneous velocity · volumetric flow · totalized volume · status word |
Materials & Construction
| Probe shaft | 316L standard · Hastelloy C-276 optional |
|---|---|
| Bluff body | 316L · Hastelloy C-276 option |
| Compression gland (retract.) | PTFE packing, stainless body |
| Piezoelectric sensor | Quartz crystal, hermetically sealed; same sensor design as LUGB-VRd (2024 China Instrument Society Top-10 award-winner in the in-line form factor) |
| Standard shaft length | 300 mm · 600 mm · 1200 mm (depending on shaft option) |
| Net weight | 2.8 kg (standard) · 4.2 kg (long) · 6.0 kg (extra-long) |
Hot-tap installation workflow
Five steps for a clean live-line install.
- Pick a location with adequate straight pipe ≥10D up / ≥5D down per LUGB standard.
- Hot-tap weld the boss + ball valve live Qualified hot-tapper welds the 1″/1.5″/2″ NPT boss (or 300LB weld-o-let if flanged).
- Drill the tap through the closed valve Hot-tap machine mounts on top of the open valve.
- Thread probe in, open valve, push to depth Thread probe into closed valve until sealed.
- Wire and verify 2-wire 24 VDC loop to electronics head; Ex d barrier in control room if hazardous.
Insertion vortex flow meter FAQ
Retrofit a live line without a shutdown?
Send pipe ID, medium, P/T range, fixed or retractable. Sized velocity, K-factor, model code, pricing in 4 hours. 5–7 days lead time.