Chemical Rotameter Flow Meter
Material-matched to your acid, alkali, chloride.
PTFE-lined / Hastelloy C / Hastelloy B / Titanium / Monel wetted
Accuracy ±1.5 % of full scale (class A)
Passive pointer build; no electronics in corrosive air
- Wetted-parts choice keyed to medium; HCl, H₂SO₄, NaOH, chlorine, HF, chloride brine
- Vertical mount, flow bottom-up; gravity-driven variable-area principle
- Pointer build is Ex-by-design (no Ex cert needed); 4-20 mA / HART option available

Variable-area rotameter for corrosive liquid and gas; HCl, H₂SO₄, NaOH, chloride brine, chlorine, and HF lines on chemical, pharma, electroplating, and pickling plants. Wetted parts match the medium: PTFE-lined for the broad acid / alkali set, Hastelloy C for chlorine and mixed acids, Hastelloy B for hot reducing acids, Titanium for chloride-rich, Monel for HF. The local pointer is the standard on corrosive service; no electronics inside to attack. DN15 to DN150, ±1.5 % of full scale.
Benefits
- Passive primary; no electronics to corrode: the pointer build reads the float without power or transmitter; acid vapor has nothing to attack inside.
- Direct visual readout: the printed scale gives a flow value at the line, no display screen to fail in a corrosive bay.
- Vertical mount, flow bottom-up: gravity sets the float reference; the line stays self-draining at the lower flange.
- Viscosity bound ≤ 5 cP: clean low-viscosity corrosive media only; viscous additives go to Coriolis at order entry.
- Ex-by-design pointer: no electronics inside, so no Ex certificate is needed for hazardous chemical bays; electrical builds add Ex d IIC T6 Gb.
- Material-matched at order entry: medium / concentration / P / T sheet goes to engineering; the build is verified against corrosion data.
- Lead time 5–7 business days from the factory.
Configure your build.
Select your specs and the configurator returns the LZD chemical-build model code plus a ballpark unit price. Submit for engineering review and material confirmation within 4 business hours.
Your Configuration
✓ Vertical mount confirmed; PTFE limits checked on P / T
✓ Reply within 4 business hours
Typical applications
Four corrosive-service applications where material-matched rotameter is the visual-indication pick.
Chemical plant acid lines
HCl, H₂SO₄, and NaOH dosing / transfer at DN15 to DN50; PTFE-lined build with passive pointer at the bay panel for operator readout.
Electroplating bath dosing
Chromium / nickel / acid-copper bath chemistry trim; PTFE or Hastelloy C wetted parts for chloride and mixed-acid resistance, low-flow visual confirmation.
Pharma chloride and HF lines
Pharma API solvent chloride streams (Monel for HF, PTFE for HCl); passive pointer for cleanroom-adjacent service, no electronics to maintain.
Pickling and scrubber chemistry
Pickling-bath acid lines and chlor-alkali scrubber bleeds; Hastelloy C or Titanium body for wet-chlorine and chloride brine service at DN25 to DN80.
Specifications
| Measurement principle | Variable-area; magnetic float rises in a vertical tapered metal tube with corrosion-resistant liner or alloy body |
|---|---|
| Pipe size range | DN15, DN20, DN25, DN32, DN40, DN50, DN65, DN80, DN100, DN125, DN150 |
| Wetted material options | PTFE-lined (steel body) / Hastelloy C / Hastelloy B / Titanium / Monel |
| Material decision matrix | PTFE for HCl / H2SO4 (≤80 %) / NaOH (≤50 %) / chlorides; Hastelloy C for chlorine / wet chlorine / mixed acids; Hastelloy B for hot reducing acids; Titanium for chloride-rich / seawater; Monel for HF / fluorides |
| Flow range (water-reference) | 0.025 m³/h (DN15 low-float) to 1,000 m³/h (DN150 high-float); other media corrected by density factor at order entry |
| Accuracy | ±1.5 % of full scale (class A) / ±2.5 % of full scale (class B) |
| Turndown | 1:10 per float calibration; multi-float order widens effective range |
| Pressure | Up to 2.5 MPa (DN15-DN50, alloy build); up to 1.6 MPa (DN65+); PTFE-lined build limited to 1.0 MPa (liner-driven) |
| Medium temperature | PTFE-lined: −40 to +85 °C (liner softens above); alloy builds: −40 to +120 °C standard; +220 °C high-T option |
| Ambient range | −40 to +65 °C |
| Indicator | Local mechanical pointer (passive, preferred for corrosive atmospheres) / electrical 4-20 mA / HART transmitter / pointer + hi-lo alarm contacts |
| Output signals | 4-20 mA / HART / pulse / RS-485 Modbus / hi-lo alarm contacts (electrical build only) |
| Display | Printed scale on local pointer; LCD instantaneous flow + totalizer on electrical build |
| Process connection | Flange PN16 / PN25 (HG/T 20592) standard; ANSI 150 / 300 lb option; NPT thread on DN15 / DN20 |
| Orientation | Vertical mount, flow bottom-up required; gravity-driven principle |
| Straight-pipe | Light demand; 5D upstream / 250 mm downstream typical |
| Power supply | 24 V DC or 220 V AC on electrical build; none on local pointer build |
| Form factor | Integrated (1) / remote split (2, electrical only) |
| Ingress protection | IP65 on electrical build; IP67 / IP68 by special order |
| Hazardous area | Ex d IIC T6 Gb on electrical build; passive (no Ex needed) on local pointer build |
| Reference standard | JB/T 9248-2015 (metal-tube variable-area flow meter), GB/T 32201-2015 industrial flow meter spec |
| Approvals | EMC 2014/30/EU on electrical build, ISO 9001 calibration certificate with each meter |
| Lead time | 5–7 business days from factory |
Installation
Five install rules. Pre-condition: medium / concentration / P / T sheet must be reviewed by engineering against corrosion data before build; material mismatch is the dominant failure mode on chemical service.
- Vertical mount, flow bottom-up; required The float rises against gravity in proportion to upward flow drag; horizontal mount removes the gravity reference and the meter cannot return to a repeatable zero. Body axis within ±2° of true vertical. Vertical mount on chemical service also keeps the lower flange self-draining (no acid puddling) and prevents gas pocketing at the upper flange.
- Confirm PTFE pressure and temperature limits before order PTFE-lined builds cap at 1.0 MPa working pressure and +85 °C medium temperature; the liner is the limit, not the flange rating. Higher pressure or temperature goes to bare-alloy (Hastelloy C, Titanium, Monel) up to 2.5 MPa and +120 °C. Send concentration, P, and T to engineering for confirmation before build.
- Upstream filter on liquid corrosive service Float-to-tube clearance is tight; particulate or precipitated salt above approximately 100 µm can jam the float or scratch the wetted surface. Install a Y-strainer in matching corrosion-resistant material upstream; PTFE-lined or alloy mesh to match the meter wetted parts.
- Damp pulsation upstream Diaphragm-pump dosing on acid lines is pulsation-heavy; the meter integrates over float oscillation, so unmitigated pulsation causes pointer jitter and biased reading. Mount downstream of an accumulator or pulsation dampener. Light straight-pipe demand: 5D upstream and 250 mm downstream of any disturbance (elbow, valve, reducer).
- Pointer build is passive; no Ex cert, no electronics to corrode Local mechanical pointer is the canonical low-cost / Ex-by-design choice for hazardous chemical bays because there are no electronics inside the meter for chlorine or acid vapor to attack. Electrical builds add Ex d IIC T6 Gb housing and 4-20 mA / HART transmitter when remote readout is needed; budget for housing-level corrosion protection on the transmitter shell.
Frequently asked questions
Need help matching material to your acid or alkali?
Send medium, concentration, P / T, flow range. Engineering verifies the build against corrosion data; lead time 5–7 business days.