Inline Ultrasonic Flow Meter
Factory-Calibrated Wafer + Flanged Pipe-Segment, DN15 to DN1200
Wafer body DN15-DN300 · flanged body DN350-DN1200
±0.5 % of rate factory-calibrated sealed unit
0 to ±12 m/s bi-directional · transit-time, no field straight-pipe penalty
- Sealed flow-tube body with built-in transducer pair; factory calibration on known internal straight-pipe length removes the field 10D/5D rule
- Reads DI, RO, glycol, hydrocarbon, and any low-conductivity liquid that electromagnetic cannot read
- OEM volume buy: custom Modbus register map, custom 4-20 mA scaling, OEM-printed label, custom calibration certificate
The Inline Ultrasonic Flow Meter drops into the pipeline as a sealed flow-tube with built-in transducer pair, factory-calibrated to ±0.5 % of rate across DN15 to DN1200. Wafer body DN15-DN300; flanged in-line DN350-DN1200. Internal calibrated length cuts the field straight-pipe rule to 3D/2D. Transit-time reads DI, RO, glycol-water, and light hydrocarbon up to 10 cSt where EMF cannot. 4-20 mA × 2, Modbus RTU, M-BUS EN 13757; HART option. AC mains or DC 8-36 V. 5–7 business days.
Benefits
- Factory-calibrated sealed flow-tube body; transducer pair built into the body; internal calibrated length cuts field rule to 3D/2D vs clamp-on 10D/5D.
- DN15 to DN1200 single-Series; wafer DN15-DN300 (shortest face-to-face); flanged DN350-DN1200 (full-bore continuity). DN200-DN300 either style.
- Reads any liquid above the noise floor regardless of conductivity; DI, RO, glycol-water, light hydrocarbon up to 10 cSt where EMF cannot read.
- ±0.5 % of rate factory-calibrated; traceable to reference master meter; certificate ships with bench-tested velocity range and accuracy class.
- Modbus RTU, M-BUS EN 13757, 4-20 mA × 2; Modbus for BMS; M-BUS for EU billing; 4-20 mA for SCADA + OEM skid. HART option.
- AC 90-260 V universal + DC 8-36 V bus; global mains without rewiring; 24 V building control supply. IP65 transmitter + IP68 flow-tube body.
- 5–7 business days factory-direct; ISO 9001 cal cert, EMC 2014/30/EU, mill-cert traceability. OEM volume supports custom register map, scaling, label, cert.
Configure your build.
Build a quotable model code from DN, body style, output, power, and accessory selection. Send the configured code with your pipeline context (medium, design pressure, BMS spec); the engineering team replies with a sized quote within one business day.
Your configuration
Applications
Industrial process water
Plant cooling-water primary, tower makeup, condensate return, demineralized supply. Wafer DN50-DN200 replaces vortex / EMF on existing flanged lines. ±0.5 % cal suits ISO 50001 EnMS.
Chilled-water primary + condenser primary
HVAC chiller plant primary on new construction; flanged DN300-DN800 fits district-cooling headers. Glycol-water tolerance covers anti-freeze loops where EMF cannot read.
DI / RO / low-conductivity process water
Pharma purified water, semicon fab DI, RO permeate, lab DI supply. Transit-time reads regardless of conductivity. 316L wetted parts on purified service.
OEM skid integration
Factory-calibrated flow-tube drops into OEM skid (cooling tower, chiller cabinet, boiler, water-treatment). Volume buy 20-200; custom register map, 4-20 mA scaling, OEM label, cert at order.
Full specifications.
| Measurement principle | Transit-time ultrasonic, factory-calibrated sealed flow-tube body with built-in transducer pair on a fixed internal straight-pipe length |
|---|---|
| Nominal diameter | DN15 to DN1200 (wafer body DN15-DN300; flanged in-line body DN350-DN1200; DN200-DN300 either body style) |
| Accuracy | ±0.5 % of rate (factory-calibrated as sealed unit, traceable to reference master meter) |
| Repeatability | 0.2 % of span |
| Velocity range | 0 to ±12 m/s, bi-directional with reverse-flow detection |
| Particulate tolerance | ≤ 10 000 ppm suspended solids |
| Medium temperature | −30 to +90 °C standard; HT version −30 to +160 °C for boiler condensate + district-heat primary |
| Compatible media | Potable / process water · DI / RO / low-conductivity water · glycol-water blends (30-50 % typical) · light hydrocarbon up to 10 cSt viscosity · treated cooling-tower water · demineralized lab supply |
| Body material | 304 stainless standard · 316L stainless corrosion-resistant · carbon steel + epoxy lining cost-down industrial water |
| Connection | Wafer between ANSI 150 / PN16 / DIN flanges · flanged in-line ANSI 150 / 300 + PN10 / PN16 / PN25 |
| Display | LCD multi-line readout showing instantaneous flow, totalizer, alarm status, diagnostics; 500 ms update rate per UFM family standard |
| Output signals | 4-20 mA × 2 (0.1 % accuracy) · RS-485 Modbus RTU · M-BUS EN 13757 · HART (factory option) · Pulse OCT |
| BMS integration | Modbus native · BACnet via Modbus gateway · KNX via converter · LonWorks via gateway · M-BUS direct EN 13757 |
| Power supply | AC 90-260 V universal mains · DC 8-36 V industrial bus |
| Power consumption | 2 W typical |
| Ingress protection | IP65 transmitter housing · IP68 flow-tube body |
| Hazardous area | Ex d available as factory custom build (NOT a standard option) |
| Install rule | 3D minimum free-pipe upstream / 2D downstream from meter inlet/outlet flanges (~1/3 the footprint of clamp-on field rule) |
| OEM options | Custom Modbus register map · custom 4-20 mA scaling · OEM-printed label · custom calibration certificate · volume-buy 20-200 units |
| Compliance ships standard | ISO 9001 calibration certificate with each meter · EMC 2014/30/EU · mill-cert traceability on body material |
| Custody-transfer certification (buyer-arranged, not shipped from factory) | OIML R75 heat metering · MID EU custody · AGA-9 North American pipeline (all NOT shipped from factory) |
| Lead time | 5 to 7 business days from factory |
Installation rules.
- Maintain 3D upstream / 2D downstream free pipe from flanges. A 90° elbow within 1D introduces profile asymmetry.
- Verify pipe-fill before measurement. Pipe must stay 100 % liquid-filled; air pockets falsify the signal. Use an air vent on the loop high point or mount on vertical-upward.
- Align flow direction with the direction arrow on the body. Reverse-flow detection works, but mounting against the arrow inverts the reading; verify direction at commissioning.
- Torque flange bolts evenly to gasket spec. Wafer body needs even torque to avoid distorting the body and shifting transducer alignment. Star pattern with a torque wrench.
- Calibrate the Modbus register map and slave address at commissioning. Factory pre-configures from BMS spec; OEM skids ship pre-configured plug-and-play.
Frequently asked questions
Need help spec’ing the build?
Send DN, body style, medium, design pressure, and BMS target. Engineering replies with transducer pair, body style, and quote in one business day.