Ultrasonic Water Meter

Battery AMR Smart Water Meter; DN15 to DN300

Residential DN15-DN25, commercial DN32-DN100, DMA primary DN150-DN300
Li-SOCl₂ primary cell, six-year typical battery service life
NB-IoT · LoRa · GPRS wireless AMR + RS-485 Modbus · M-BUS · pulse wired output

  • No moving parts; transit-time physics with 10-year-plus service life and no recalibration walks
  • Smart-card prepaid + valve-control integration on the V62 firmware version for prepaid utility billing markets
  • IP68 submersible body for buried-chamber and pit-mount installation
↓ Request datasheet (PDF)
2 358.62 m3 DN50 · V62 · NB-IoT 📶 NB-IoT 📡 LoRa 📱 GPRS Li-SOCl₂ 6-year battery · transit-time, no moving parts Residential · Commercial · DMA · IP68 submersible

The Ultrasonic Water Meter is an integrated battery AMR meter for residential, commercial, and DMA billing across DN15 to DN300. Transit-time in a sealed body; no impeller, no bearings, no register gearing. Li-SOCl₂ cell delivers six-year service. Wireless AMR covers NB-IoT, LoRa, and GPRS across firmware V56–V64; V62 adds smart-card prepaid and valve control. IP68 submersible. 5–7 business days from the factory with ISO 9001 cal cert.

Benefits

  • Six-year Li-SOCl₂ battery; stock duty cycle, hourly upload, sealed inside the IP68 body. Meter swapped as a unit at end of life.
  • NB-IoT, LoRa, or GPRS wireless AMR; firmware V62 (NB-IoT + prepaid), V63 (LoRa), V64 (multi-protocol).
  • No moving parts, 10-year service life; transit-time reads residential trickle flows below the mechanical Q1 floor.
  • Smart-card prepaid and valve control on V62; meter decrements as water is consumed; valve closes at zero balance until the next top-up.
  • RS-485 Modbus RTU, M-BUS EN 13757, pulse, IP68 submersible; threaded ISO 228 G on DN15–DN50, flanged PN10/PN16 on DN65–DN300.

Configure your build.

Build a model code from DN, wireless version, prepaid option, output, and connection. Send the code with the application, the local mobile coverage, and any prepaid or cert requirements. Engineering replies with a sized quote within one business day.

Your configuration

PF-UWM-DN20-V62-N-M-G-1
DN20 residential standard, V62 firmware (NB-IoT + smart-card prepaid + valve control capable), postpaid mode, RS-485 Modbus + M-BUS + pulse output, threaded ISO 228 G, +0.1 to +50 °C potable water.
Estimated unit price $ 215
Request engineering quote Request datasheet

Applications

🏠

Residential utility billing; new build + retrofit replace

DN15 to DN25 entry meters for apartment and single-family service. V62 firmware adds smart-card prepaid for collection-risk markets.

🏢

Commercial building entry + tenant sub-measurement

DN32 to DN100 commercial entry plus tenant sub-measurement via RS-485 Modbus and M-BUS into the BMS. LEED audit trail via continuous data log.

📊

DMA non-revenue-water audit

DN100 to DN300 boundary meters tile the distribution network. NB-IoT or LoRa streams 15-minute totalizer to SCADA; nightly minimum flow exposes background leakage.

🏗️

HVAC chilled-water + hot-water tenant chargeback

DN50 to DN200 chilled-water primary and DHW sub-measurement. Extended-range versions handle DHW; M-BUS EN 13757 feeds the tenant-billing aggregator.

Full specifications.

Measurement principleTransit-time ultrasonic, integrated sealed body with no moving parts
Nominal diameterDN15 to DN300 (residential DN15-DN25, commercial DN32-DN100, DMA primary DN150-DN300)
ConnectionThreaded ISO 228 G per DN15-DN50; flanged PN10 / PN16 per DN65-DN300
BatteryLithium thionyl chloride (Li-SOCl₂) primary cell, six-year typical service life on stock duty cycle; sealed inside body, not field-replaceable; meter swapped at end-of-life
Wireless outputNB-IoT (V62 + V64 firmware) · LoRa (V63 + V64) · GPRS 2G (V61 + V64) · version-dependent
Wired outputRS-485 Modbus RTU · pulse · M-BUS (EN 13757 European HVAC)
Output signalsWireless (NB-IoT · LoRa · GPRS) or wired (Modbus RTU · pulse · M-BUS) per firmware version; see Wireless output and Wired output rows above for version-specific channel detail
Smart-card prepaidOptional on V62 firmware version; integrated valve-control output drives NO or NC solenoid; emergency-override codes from utility back-office
DisplayIntegral LCD with firmware menu (M00-M2A multi-level)
LoggingStock duty cycle: 15-minute interval; configurable per firmware version; flow, totalizer, alarm, battery state stored locally
AccuracyR-class typology per ISO 4064 (higher R = wider rangeability at the low-flow turndown; R80/R100/R200 verified at order) against the buyer’s local metrology authority
RepeatabilityEmbedded in the ISO 4064 R-class typology; the standard’s accuracy range at Q1, Q2, Q3, Q4 brackets both bias and spread; not separately declared on the meter datasheet
Velocity rangeOperating range factory-set per nominal diameter to match the meter’s intended Qmin-Qmax flow range
Power supplyBattery-only (no mains power required; see Battery row above)
Power consumptionMicro-watt sleep-cycle architecture; Li-SOCl₂ primary cell delivers six-year typical service on stock 15-minute Modbus poll duty cycle; not separately rated in watts on a battery-driven meter
Hazardous areaNot applicable on battery-only meter (no electrical hazard at meter body)
Medium temperature+0.1 to +50 °C standard (potable water); extended-range versions available on commercial / industrial firmware; verify upper limit at order
Ambient temperature−25 to +55 °C operating · −30 to +70 °C storage
Firmware familyV56 · V60 · V61 · V62 · V63 · V64 multi-generation
Ingress protectionIP68 submersible (buried-chamber and pit-mount service)
Working pressure≤ 1.0 MPa standard; ≤ 1.6 MPa flanged version
ISO 9001 cal certIssued with each meter, lists serial number, calibrated flow range, and tested accuracy class
ComplianceEMC 2014/30/EU (Annex II)
Custody-transfer certification (buyer-arranged, not shipped from factory)ISO 4064 R-class custody · OIML R49 · MID MI-001 (EU custody) · NSF/ANSI 61 · WRAS UK · ACS France · DVGW Germany · KC Korea
Lead time5 to 7 business days from factory

Installation rules.

  1. Respect the 10D upstream / 5D downstream straight-pipe rule. Mount on the longest available run from any elbow, valve, or reducer.
  2. Orient per the flow-direction arrow stamped on the body. Most versions are uni-directional; specify the bi-directional firmware at order if needed.
  3. Verify pipe-fill at commissioning and on annual service walks. The pipe must stay 100 % liquid-filled; air pockets falsify the transit-time signal.
  4. Plan for a 6-year battery swap. Document the install date; the meter is swapped as a unit at end of battery life.
  5. Set the wireless version at order. Field changes require a meter swap, so pick the version that matches the local network before install.

Frequently asked questions

Why pick ultrasonic over mechanical (rotary piston, multi-jet, Woltmann)?+
Three reasons. No moving parts to wear out, so 10-year service life without recalibration walks. Low-flow sensitivity catches trickle leakage below the mechanical Q1 floor. Native wireless AMR avoids the mechanical add-on register and battery module.
How does DMA non-revenue-water audit work?+
The boundary meter reads inflow continuously. NB-IoT or LoRa streams the totalizer to SCADA every 15 minutes. Compare DMA inflow to billed-tenant consumption; the difference is non-revenue water. Nightly minimum flow between 02:00 and 04:00 is the most sensitive leak indicator on a static distribution system.
NB-IoT vs LoRa vs GPRS; which one fits my deployment?+
NB-IoT fits urban utilities on the mobile NB-IoT frequencies. LoRa fits utility-private gateway networks in rural or suburban areas. GPRS/2G fits legacy 2G markets in Asia. Specify at order: V62 (NB-IoT), V63 (LoRa), V64 (multi-protocol).
What battery service life can I expect?+
Six years on stock duty cycle (hourly upload, 15-minute logging). Per-minute logging shortens to four years; daily upload extends past ten. The Li-SOCl₂ cell is sealed inside the IP68 body and is not field-replaceable; the meter is swapped as a unit at end of life.
What is the lead time and what cert ships standard?+
Lead time is 5 to 7 business days from order confirmation, factory direct. Every meter ships with an ISO 9001 calibration certificate, an EMC 2014/30/EU certificate, and a mill-cert traceability note. ISO 4064, OIML R49, MID MI-001, NSF/ANSI 61, WRAS, ACS, DVGW, and KC are buyer-arranged with the local notified body.

Need help spec’ing the build?

Send DN range, application, wireless preference, and whether prepaid + valve control is in scope. Engineering replies with firmware version and quote in one business day.