Ultrasonic Water Meter
Battery AMR Smart Water Meter; DN15 to DN300
Residential DN15-DN25, commercial DN32-DN100, DMA primary DN150-DN300
Li-SOCl₂ primary cell, six-year typical battery service life
NB-IoT · LoRa · GPRS wireless AMR + RS-485 Modbus · M-BUS · pulse wired output
- No moving parts; transit-time physics with 10-year-plus service life and no recalibration walks
- Smart-card prepaid + valve-control integration on the V62 firmware version for prepaid utility billing markets
- IP68 submersible body for buried-chamber and pit-mount installation
The Ultrasonic Water Meter is an integrated battery AMR meter for residential, commercial, and DMA billing across DN15 to DN300. Transit-time in a sealed body; no impeller, no bearings, no register gearing. Li-SOCl₂ cell delivers six-year service. Wireless AMR covers NB-IoT, LoRa, and GPRS across firmware V56–V64; V62 adds smart-card prepaid and valve control. IP68 submersible. 5–7 business days from the factory with ISO 9001 cal cert.
Benefits
- Six-year Li-SOCl₂ battery; stock duty cycle, hourly upload, sealed inside the IP68 body. Meter swapped as a unit at end of life.
- NB-IoT, LoRa, or GPRS wireless AMR; firmware V62 (NB-IoT + prepaid), V63 (LoRa), V64 (multi-protocol).
- No moving parts, 10-year service life; transit-time reads residential trickle flows below the mechanical Q1 floor.
- Smart-card prepaid and valve control on V62; meter decrements as water is consumed; valve closes at zero balance until the next top-up.
- RS-485 Modbus RTU, M-BUS EN 13757, pulse, IP68 submersible; threaded ISO 228 G on DN15–DN50, flanged PN10/PN16 on DN65–DN300.
Configure your build.
Build a model code from DN, wireless version, prepaid option, output, and connection. Send the code with the application, the local mobile coverage, and any prepaid or cert requirements. Engineering replies with a sized quote within one business day.
Your configuration
Applications
Residential utility billing; new build + retrofit replace
DN15 to DN25 entry meters for apartment and single-family service. V62 firmware adds smart-card prepaid for collection-risk markets.
Commercial building entry + tenant sub-measurement
DN32 to DN100 commercial entry plus tenant sub-measurement via RS-485 Modbus and M-BUS into the BMS. LEED audit trail via continuous data log.
DMA non-revenue-water audit
DN100 to DN300 boundary meters tile the distribution network. NB-IoT or LoRa streams 15-minute totalizer to SCADA; nightly minimum flow exposes background leakage.
HVAC chilled-water + hot-water tenant chargeback
DN50 to DN200 chilled-water primary and DHW sub-measurement. Extended-range versions handle DHW; M-BUS EN 13757 feeds the tenant-billing aggregator.
Full specifications.
| Measurement principle | Transit-time ultrasonic, integrated sealed body with no moving parts |
|---|---|
| Nominal diameter | DN15 to DN300 (residential DN15-DN25, commercial DN32-DN100, DMA primary DN150-DN300) |
| Connection | Threaded ISO 228 G per DN15-DN50; flanged PN10 / PN16 per DN65-DN300 |
| Battery | Lithium thionyl chloride (Li-SOCl₂) primary cell, six-year typical service life on stock duty cycle; sealed inside body, not field-replaceable; meter swapped at end-of-life |
| Wireless output | NB-IoT (V62 + V64 firmware) · LoRa (V63 + V64) · GPRS 2G (V61 + V64) · version-dependent |
| Wired output | RS-485 Modbus RTU · pulse · M-BUS (EN 13757 European HVAC) |
| Output signals | Wireless (NB-IoT · LoRa · GPRS) or wired (Modbus RTU · pulse · M-BUS) per firmware version; see Wireless output and Wired output rows above for version-specific channel detail |
| Smart-card prepaid | Optional on V62 firmware version; integrated valve-control output drives NO or NC solenoid; emergency-override codes from utility back-office |
| Display | Integral LCD with firmware menu (M00-M2A multi-level) |
| Logging | Stock duty cycle: 15-minute interval; configurable per firmware version; flow, totalizer, alarm, battery state stored locally |
| Accuracy | R-class typology per ISO 4064 (higher R = wider rangeability at the low-flow turndown; R80/R100/R200 verified at order) against the buyer’s local metrology authority |
| Repeatability | Embedded in the ISO 4064 R-class typology; the standard’s accuracy range at Q1, Q2, Q3, Q4 brackets both bias and spread; not separately declared on the meter datasheet |
| Velocity range | Operating range factory-set per nominal diameter to match the meter’s intended Qmin-Qmax flow range |
| Power supply | Battery-only (no mains power required; see Battery row above) |
| Power consumption | Micro-watt sleep-cycle architecture; Li-SOCl₂ primary cell delivers six-year typical service on stock 15-minute Modbus poll duty cycle; not separately rated in watts on a battery-driven meter |
| Hazardous area | Not applicable on battery-only meter (no electrical hazard at meter body) |
| Medium temperature | +0.1 to +50 °C standard (potable water); extended-range versions available on commercial / industrial firmware; verify upper limit at order |
| Ambient temperature | −25 to +55 °C operating · −30 to +70 °C storage |
| Firmware family | V56 · V60 · V61 · V62 · V63 · V64 multi-generation |
| Ingress protection | IP68 submersible (buried-chamber and pit-mount service) |
| Working pressure | ≤ 1.0 MPa standard; ≤ 1.6 MPa flanged version |
| ISO 9001 cal cert | Issued with each meter, lists serial number, calibrated flow range, and tested accuracy class |
| Compliance | EMC 2014/30/EU (Annex II) |
| Custody-transfer certification (buyer-arranged, not shipped from factory) | ISO 4064 R-class custody · OIML R49 · MID MI-001 (EU custody) · NSF/ANSI 61 · WRAS UK · ACS France · DVGW Germany · KC Korea |
| Lead time | 5 to 7 business days from factory |
Installation rules.
- Respect the 10D upstream / 5D downstream straight-pipe rule. Mount on the longest available run from any elbow, valve, or reducer.
- Orient per the flow-direction arrow stamped on the body. Most versions are uni-directional; specify the bi-directional firmware at order if needed.
- Verify pipe-fill at commissioning and on annual service walks. The pipe must stay 100 % liquid-filled; air pockets falsify the transit-time signal.
- Plan for a 6-year battery swap. Document the install date; the meter is swapped as a unit at end of battery life.
- Set the wireless version at order. Field changes require a meter swap, so pick the version that matches the local network before install.