Quick-Install Ultrasonic Flow Meter (Small-Pipe Non-Weld, DN15–DN32)
Outer-Mount on OD20 to OD40 Host Pipe, ±1.0 % Accuracy, IP66 Wet-Service Tolerance
Transit-time outer-mount, accuracy spec ±1.0 % at 0.3 to 5 m/s (relaxes to ±2.0 % outside that spec)
24 V DC, 3 W. IP66 transmitter housing
Modbus RTU, 4-20 mA, OCT (open-collector transistor) pulse
- Integrated clamp body fits four metric ODs only; 20 / 25 / 32 / 40 mm. Confirm host-pipe OD before order; ANSI Sch-40 steel (OD 21.3 / 26.7 / 33.4 / 42.2 mm) and Type-L copper (OD 15.9 / 22.2 / 28.6 / 35 mm) do not match.
- 1.54-inch IPS LCD 240 x 240, four-direction screen rotation for sideways mounting; m³/h, LPM, mL/min, GPM, LPH selectable.
- Suits residential entry meters, commercial sub-utility branches, lab dosing skids, OEM small-loop carts.

The Quick-Install Ultrasonic Flow Meter is a transit-time instrument for small-pipe service DN15 to DN32. The meter mounts on the host pipe outer surface in an integrated clamp body sized to OD 20, 25, 32, or 40 mm; no pipe cut, no weld, no shutdown. ±1.0 % of reading at 0.3 to 5 m/s; repeatability 0.4 %. 1.54-inch IPS LCD. Modbus RTU, 4-20 mA, OCT pulse. IP66 wet-service tolerance. 24 V DC, 3 W. 5–7 business days.
Benefits
- Outer-mount non-weld retrofit. Integrated clamp body bolts around the host pipe with two screws. No pipe cut, no weld, no shutdown. ~30 minutes per meter, field installer needs the OD-matched clamp.
- Pre-aligned transducer spacing per OD. Each clamp body holds the transducer pair at the specified spacing for the matched host OD. No field-spacing measurement, no acoustic-coupling calibration.
- DN15 to DN32 small-pipe slot. Residential entry, commercial sub-utility branch, lab dosing, OEM small-loop. Outside DN15-DN32, go to the compact clamp-on family (DN6-DN200) or the inline counterparts.
- IP66 wet-service tolerance. Tolerates direct water jets and chemical splash; survives residential pits, commercial sub-meter chambers, lab cabinets that get wash-down.
- 1.54-inch IPS LCD 240 x 240. 4-direction rotation. Modbus RTU + 4-20 mA + OCT pulse. Optional 30 V DC at 1 A relay. 24 V DC, 3 W. 5–7 business days from the factory.
Configure your build.
Build a model code from host-pipe OD, output, and accessory selection.
Your configuration
Applications
Residential and commercial sub-utility
Residential entry meters, apartment sub-measurement, commercial DHW return, building sub-utility taps on OD 20 to OD 40 host pipe.
Lab and dosing skids
Lab water supply, DI cart sub-loop, chemical dosing reference line. IP66 housing tolerates wash-down and splash.
OEM small-loop carts
Mobile dosing cart, instrument calibration skid, lab analytical cart. Small-pipe outer-mount fits OEM panel layouts.
Small-pipe verification
Cross-check a primary inline meter on a DN15-DN32 branch. ±1.0 % accuracy is tight enough to flag a 3 % drift.
Full specifications.
| Measurement principle | Transit-time ultrasonic; outer-mount integrated clamp body on host pipe; firmware times the upstream and downstream transit difference |
|---|---|
| Host pipe range | OD 20 / OD 25 / OD 32 / OD 40 mm (DN15 to DN32) |
| Nominal diameter | DN15 to DN32 (matches host OD 20 to OD 40) |
| Channels | 1 acoustic path (single-path transit-time) |
| Install style | Outer-mount integrated clamp body sized to host pipe OD; bolts with two screws; no pipe cut, no weld |
| Optional BTU pair | Not available on this model; for BTU sub-measurement on small pipe, go to the compact clamp-on family (BTU version) or to the inline BTU meter |
| Accuracy | ±1.0 % of reading at velocity 0.3 to 5 m/s |
| Linearity | ±1.0 % at velocity 0.3 to 5 m/s |
| Repeatability | 0.4 % of span |
| Velocity range | 0.1 to 10 m/s operating; accuracy spec ±1.0 % within 0.3 to 5 m/s |
| Response time | 500 ms |
| Display | 1.54-inch IPS LCD 240 x 240 with 4-direction rotation; unit selection m³/h, LPM, mL/min, GPM, LPH |
| Output; analog | 4-20 mA, max load 600 ohm |
| Output; digital | RS-485 Modbus RTU |
| Output; other | OCT pulse + high / low alarm; relay 30 V DC at 1 A (factory option) |
| Power | 24 V DC, 3 W |
| Medium | Single-phase liquid, 100 % pipe-fill; water, aqueous solution, chemical reagent; suspended solids 4 % or less |
| Medium temperature | 0 to +60 deg C |
| Ambient temperature | 0 to +60 deg C operating |
| Ingress protection | IP66 transmitter housing (tolerates direct water jets and chemical splash) |
| Pipe materials supported | Steel, stainless, copper, PVC, PE, HDPE (acoustic-coupling treatment may be needed on cement-lined or scale-coated host pipe) |
| Process connection | Outer-mount clamp body; no process port on the meter; bolts to the host pipe OD (20, 25, 32, or 40 mm) |
| Hazardous area | Not declared on this model; route Ex-classified service to the full-size clamp-on or insertion counterpart with CNEX Ex d IIC certificate |
| Compliance ships standard | Calibration record with each meter (serial number + tested flow range); ISO 9001 calibration certificate; mill-cert traceability on the body |
| Lead time | 5–7 business days from factory |
Installation rules.
- Confirm host-pipe OD before order. Four sizes only; OD 20 / 25 / 32 / 40 mm. Outside these, go to the compact clamp-on family.
- 10D upstream, 5D downstream straight-pipe (D = host-pipe diameter). Short runs degrade accuracy below the ±1.0 % spec.
- Bolt the clamp body around the host pipe and torque per spec. Even torque on both screws keeps transducer alignment; the integrated coupling layer mates against the pipe wall.
- Verify 100 % pipe-fill at commissioning. Air pockets falsify the signal. Mount horizontal or vertical-upward.
- Configure Modbus register and slave address at commissioning. Factory pre-configures from BMS or DCS spec; record both in the commissioning log.
Frequently asked questions
Need help spec’ing this meter?