Four-Path Ultrasonic Flow Meter (4-Channel)
Four Paths for Very-Large-Bore Pipe, DN25 to DN5000
±0.5 % at 0.5 to 5 m/s, repeatability 0.10 %
4 paths sample ~80 % of the cross-section profile
Modbus RTU, 4-20 mA, OCT pulse, relay
- Tolerates severe upstream disturbance (double elbow out-of-plane, half-open valve) that defeats 1- and 2-path meters.
- Optional PT100 supply + return pair turns the same body into a kWh / MJ / BTU heat meter with audit-trail redundancy.
- 24 V DC, 3-5 W. IP54 transmitter, IP68 wetted transducer.

The Four-Path Ultrasonic Flow Meter is a 4-channel transit-time instrument for liquid service, DN25 to DN5000. Four paths sample about 80 % of the velocity profile across the cross-section. Accuracy ±0.5 % at 0.5 to 5 m/s, repeatability 0.10 %. C8 inline or W8 split-body wall-mount. Optional PT100 pair for kWh / MJ / BTU output. Modbus RTU, 4-20 mA, OCT pulse. 24 V DC. 5–7 business days from the factory.
Benefits
- 4 paths sample the cross-section evenly. Four planes cover roughly 80 % of the velocity profile; 2-path covers about 60 %. The gap matters on very-large-bore lines.
- ±0.5 % across DN25 to DN5000. Velocity 0.5 to 5 m/s. Linearity ±0.5 %, repeatability 0.10 %. Four path readings cross-check each other; the firmware flags drift on any one path.
- Tolerates severe upstream disturbance. Double elbow out-of-plane, half-open valve immediately upstream; the 4-path average converges where a 1- or 2-path meter cannot. Suits constrained retrofits.
- Optional PT100 pair returns kWh / MJ / BTU. Same transmitter, two PT100 inputs, on-board calorimetry. Suits district-heat substation primary and large-bore HVAC tenant chargeback.
- Modbus RTU + 4-20 mA + OCT pulse + relay. 24 V DC, 3-5 W. Response 500 ms. Pre-configured slave address ships with each meter.
Configure your build.
Build a model code from DN, install style, BTU option, output, and power. Send the code with the application and upstream-pipe context. Engineering replies with a sized quote within one business day.
Your configuration
Applications
Very-large-bore custody trunk
Water-utility DN1500 to DN5000 primary metering. 4-path closes the large-bore profile under-sampling gap that limits 1- and 2-path meters. Calibration record ships with each meter.
Severe-disturbance retrofit
Refinery or petrochemical install between a double elbow out-of-plane and a half-open valve. The 4-path average tolerates disturbance that defeats lower-path counts.
District-heat primary (with BTU)
Large-bore substation entry with the optional PT100 pair. Returns kWh / MJ / BTU on Modbus. Suits 40 to 90 K delta-T.
Fiscal sub-meter audit trail
Four path readings cross-check each other; the firmware flags drift on any one path. Suits utility chargeback and tenant billing audit trails.
Full specifications.
| Measurement principle | 4-channel transit-time ultrasonic; four acoustic chord paths on offset planes; firmware applies Gaussian-quadrature path weights to combine chord velocities into cross-section mean velocity |
|---|---|
| Channels | 4 chord paths |
| Nominal diameter | DN25 to DN5000 |
| Accuracy | ±0.5 % of reading at velocity 0.5 to 5 m/s |
| Linearity | ±0.5 % |
| Repeatability | 0.10 % |
| Velocity range | 0.1 to 12 m/s operating; accuracy spec ±0.5 % within 0.5 to 5 m/s |
| Response time | 500 ms |
| Install style | C8 integral inline body (transmitter on the flow body) OR W8 split-body wall-mount (transducer set on the line, remote transmitter on the wall, armoured signal cable) |
| Optional BTU pair | PT100 supply + return pair; on-board firmware solves E = integral of (m-dot x Cp x delta-T) dt; output kWh / MJ / BTU selectable on display and on the 4-20 mA energy-rate channel |
| Output; analog | 4-20 mA, max load 600 ohm |
| Output; digital | RS-485 Modbus RTU |
| Output; other | OCT pulse + high / low alarm; relay 30 V DC at 1 A, switching frequency under 2 Hz |
| Power | 24 V DC, 3-5 W |
| Display | LCD 5.0-inch IPS, 800 × 480 resolution, 4-direction rotation; unit selection m³/h, LPM, mL/min, GPM, LPH |
| Medium | Single-phase liquid, 100 % pipe-fill; water, aqueous solution, chemical reagent; suspended solids 4 % or less |
| Medium temperature | −40 to +80 deg C (sensor head) |
| Ambient temperature | −40 to +60 deg C transmitter; −40 to +80 deg C sensor head |
| Ingress protection | IP54 transmitter housing; IP68 wetted transducer head |
| Process connection | Flange ANSI B16.5 / EN 1092-1 / GB/T 9119 (specify at order) |
| Hazardous area | Not declared on this model; route Ex-classified service to clamp-on or insertion ultrasonic model with CNEX Ex d IIC certificate |
| Compliance ships standard | Calibration record with each meter (serial number + tested flow range); notified-body custody-transfer certificate is buyer-arranged with the local metrology authority |
| Lead time | 5–7 business days from factory |
Installation rules.
Five rules keep 4-path averaging accurate.
- 5D upstream, 3D downstream straight-pipe. The 4-path average tolerates more upstream disturbance than lower-path meters; hold 10D after pumps.
- Orient the chord planes off the elbow plane. The four-chord average converges fastest when each chord crosses a different sector of the profile.
- Pipe must stay 100 % liquid-filled. Air pockets falsify the transit-time signal on all four paths. Closed loops need an air vent upstream of the meter.
- Mount W8 transmitter on a stable wall, −40 to +60 deg C ambient. IP54 housing; plant room, not outdoor submerged service.
- Configure register map and slave address at commissioning. Factory pre-configures from BMS or DCS spec. Record both in the commissioning log.
Frequently asked questions
Need help spec’ing the 4-path meter?
Send DN, service liquid, upstream pipe geometry, install style, and BTU option. Sized quote within one business day. Lead time 5–7 business days.