Multi-Hole Orifice Plate Flow Meter

Lower noise, shorter straight-pipe runs.

DN50 to DN1200 · ±0.5 % of flow · ISO 5167
PN0.6 to PN42 MPa · −200 to +800 °C
Beta 0.20 to 0.75 · corner / D & D/2 / flange taps

  • Multi-hole disc splits one jet into several smaller jets; lower aerodynamic noise on noise-sensitive lines
  • Velocity profile recovers faster than a single-hole orifice; shorter upstream run inside the ISO 5167 table
  • Transmitter-flexible: pair with buyer-supplied Rosemount 3051, Yokogawa EJA, Honeywell ST3000, or order the integrated build
↓ Request datasheet (PDF)
Multi-hole orifice plate flow meter with paired flanges, multi-hole balanced disc, and impulse-line takeoffs to DP transmitter

Multi-hole disc · corner / D & D/2 / flange taps · ISO 5167

Several smaller jets → lower noise · faster velocity-profile recovery

Multi-hole orifice plate flow meters are designed to measure clean liquid, gas, and steam through a perforated disc primary element that follows ISO 5167 / GB/T 2624 conventions. The multi-hole pattern splits the single jet of a standard orifice into several smaller jets at lower velocity, which lowers downstream aerodynamic and hydrodynamic noise and conditions the velocity profile faster than a single bore. DN50 to DN1200, PN0.6 to PN42 MPa, −200 to +800 °C, ±0.5 % of flow. Pair with a buyer-supplied Rosemount 3051, Yokogawa EJA, or Honeywell ST3000 DP transmitter, or order the integrated build with a factory-mounted ProFlow DP transmitter on a 3-valve manifold. Ships 5–7 business days.

Benefits

  • Lower jet noise: several smaller jets in place of one large jet; useful on residential-adjacent HVAC, lab, and food-process headers where line noise is a complaint.
  • Shorter upstream run inside the ISO 5167 table: the multi-hole pattern conditions the velocity profile faster, so 22 D to 30 D upstream typically meets spec where a single-hole orifice would need the full 30 D to 50 D.
  • DN50 to DN1200 pipe range with corner taps, D and D/2 taps, or flange taps per ISO 5167-2; flange material matched to the pipe schedule.
  • PN0.6 to PN42 MPa pressure rating across −200 to +800 °C medium temperature; covers cryogenic LN2/LOX/LH2 through superheated steam.
  • Wetted material options: 304 / 316 / 316L / 321 stainless steel standard; 12CrMo and Cr5Mo chrome-moly for hot steam; Hastelloy, Monel, and Titanium by quote for chemical service.
  • Transmitter-flexible: order element-only and pair with a buyer-supplied Rosemount 3051 / Yokogawa EJA / Honeywell ST3000, or order the integrated build with a factory ProFlow DP transmitter at 4-20 mA, HART, or RS-485 Modbus.
  • Lead time 5–7 business days from the factory.

Configure your build.

Pick pipe DN, pressure rating, wetted material, tap geometry, and DP transmitter option. The configurator returns the PF-LG-PH model code and a ballpark unit price; engineering replies with a sized β and quote within one business day.

Your Configuration

PF-LG-PH-50-1.6-2-C-F-N-N
DN50 pipe at PN1.6 MPa, 316 stainless steel wetted, corner taps on HG/T 20592 flanges, primary element only (buyer-supplied DP transmitter).
Estimated unit price
Verified after engineering sizing
$1,200
Request Quote on This Build Email Engineering
✓ Sized β returned with quote
✓ ISO 5167 / GB/T 2624 wet-flow cal cert
✓ Reply within 4 business hours

Typical applications

Four applications where the multi-hole disc earns its place over a single-hole orifice.

🏠

Residential-adjacent HVAC headers

Chilled-water and condenser risers in offices, hospitals, and hotels where line noise carries to occupied spaces. Several smaller jets drop the broadband noise the single jet of a standard orifice creates.

🧪

Lab utility and process headers

Compressed-air, instrument-air, and cooling-water runs in research labs and pilot lines where short straight-pipe sections and noise complaints both matter. The multi-hole disc handles both at once.

🍲

Food and beverage process water

Process-water and CIP supply on food-grade plants where line noise reaches packaging floors. The element ships in 316L stainless; sanitary CIP/SIP geometry is not in scope; route sanitary service to Coriolis or EMF.

⚡

High-pressure steam and gas let-down

Saturated and superheated steam headers and high-pressure natural-gas let-down stations where the disc both measures flow and conditions the jet profile after the pressure-reducing valve. PN42 MPa rating covers main-steam and trunkline service.

Specifications

Measurement principleDifferential-pressure primary element; multi-hole disc creates a ΔP that scales with the square of volumetric flow per ISO 5167 / Bernoulli; DP transmitter applies square-root extraction to output flow
Accuracy±0.5 % of flow per ISO 5167 wet-flow cal on the factory loop
Repeatability±0.1 % typical for an ISO 5167 conformant install
Reference standardISO 5167 / GB/T 2624 (Chinese national adoption of ISO 5167 series)
Pipe sizeDN50 to DN1200
Pressure ratingPN0.6 / 1.0 / 1.6 / 2.5 / 4.0 / 6.4 / 10 / 16 / 25 / 42 MPa
Medium temperature−200 to +800 °C
Beta ratio0.20 to 0.75; sized by quote against flowing P, T, and ΔP budget
Tap geometryCorner taps / D and D/2 taps / Flange taps (1″ from each face), per ISO 5167-2
Wetted material304 / 316 / 316L / 321 stainless steel standard; 12CrMo and Cr5Mo chrome-moly for hot steam service; Hastelloy, Monel, Titanium by quote
Flange standardHG/T 20592 PN rating standard; ANSI 150 / 300 / 600 / 900 / 1500 lb by order
Applicable mediaClean liquid (water, glycol, refined hydrocarbon, condensate, cryogenic LN2/LOX/LH2/LAr), clean gas (air, N2, O2, CO2, natural gas, hydrogen, instrument air), saturated and superheated steam; single-phase, full-pipe
Turndown1:3 with standard 4-20 mA DP transmitter; 1:7 to 1:10 with HART smart transmitter
DP transmitter optionNone (buyer-supplied) / ProFlow 4-20 mA HART (separately mounted within 3 m) / integrated build (factory-mounted with 3-valve manifold)
Output signal (integrated build)4-20 mA loop / HART / RS-485 Modbus RTU
Hazardous-area certification (integrated build)Ex d IIC T6 Gb on the DP transmitter housing; the mechanical primary element is passive and needs no Ex cert
Ingress protection (integrated build)IP65 standard; IP66/67 by special order
Calibration certificateISO 5167 / GB/T 2624 wet-flow cal on the factory loop; ISO 9001 quality cert; mill cert traceable to heat number on the wetted-metal grade
Lead time5–7 business days from factory

Installation

Five field rules for an ISO 5167 conformant install and a stable DP signal.

  1. Upstream straight pipe per the ISO 5167 table The LG series table applies: for a single 90° elbow at β = 0.5 the upstream run is 22 D and downstream 5 D; at β = 0.75 the upstream run is 44 D; two elbows in different planes call for 50 D upstream; a reducer is 16 D; a regulator or control valve is 30 D or use a flow conditioner. The multi-hole disc lets the velocity profile recover faster, so 22 D to 30 D upstream typically meets spec on the easier disturbance cases.
  2. Horizontal orientation preferred; flow direction stamped on the disc body Horizontal is the standard for liquid and gas. For steam and condensable gas, mount horizontally with impulse lines sloped downward to the transmitter so condensate drains back. Vertical mount is permitted with the flow direction marked; do not flip the disc; the published β and discharge coefficient are direction-specific.
  3. Pick tap geometry to match the install Corner taps are flush to the disc carrier ring; compact, lowest install effort. D and D/2 taps sit one pipe diameter upstream and half a diameter downstream; classical convention, slightly tighter accuracy on small bore. Flange taps sit 25.4 mm (1 inch) from each face of the plate; the most common choice for DN50 to DN600 service because the flange already carries the bosses.
  4. Impulse lines sloped 1:10 toward the transmitter for liquid, toward the primary for gas Use 8 to 12 mm OD stainless tubing with a 3-valve or 5-valve manifold at the transmitter. Keep total impulse length under 5 m to minimize lag. Add steam-tracing or electric heat-tracing on cold-ambient runs (below 0 °C ambient) with liquid or condensable gas in the lines; the build does not ship a heat-trace option; buyer responsibility.
  5. Zero the DP transmitter after install with the line pressurized and flow stopped Open the equalizing valve at the manifold (cell sees zero ΔP under static pressure), zero the transmitter against the sized URL, then close the equalizing valve and open the isolation valves to put the cell back in service. Record the baseline offset; routine re-zero every 6 to 12 months catches drift before it shows up on the totalized reading.

Frequently asked questions

What is a multi-hole orifice plate flow meter and how is it different from a standard single-hole orifice?+
A multi-hole orifice plate is a differential-pressure primary element with a perforated disc rather than a single concentric bore. The single jet of a standard orifice is split into several smaller jets, each with lower velocity and a tighter wake. Two field outcomes follow. First, the aerodynamic and hydrodynamic noise of the jet collapse downstream is meaningfully lower; useful on residential-adjacent HVAC, lab utility, and food-process lines where line noise is a complaint. Second, the multi-hole pattern acts as a flow conditioner; the velocity profile recovers faster than a single-jet orifice, which reduces the upstream straight-pipe length the install actually needs. Accuracy is the same ISO 5167 ±0.5 % of flow as a standard orifice when β, taps, and straight-pipe length are within the sizing table. The product is also marketed as a ‘balanced flow meter’ by some Chinese OEMs.
What is the upstream straight-pipe requirement and how does it compare to a single-hole orifice?+
The LG series applies the same straight-pipe table as the rest of the LG primary-element series per ISO 5167. For a single 90° elbow at β = 0.5 the upstream run is 22 D and the downstream run is 5 D; at β = 0.75 the upstream run is 44 D. Two elbows in different planes call for 50 D upstream. The multi-hole disc shortens the practical run because the jet pattern conditions the velocity profile faster than a single bore, so installs with 22 D to 30 D upstream typically meet the spec where a single-hole orifice would have needed the full 30 D to 50 D. ProFlow does not publish a separate shorter table; the sizing table is the contract; the multi-hole disc is the extra margin within it. For installs with less than 10 D upstream, quote an averaging-pitot or a Coriolis.
What is in scope and what is out of scope for the multi-hole orifice?+
In scope: clean liquid (water, glycol, refined hydrocarbon, condensate, cryogenic LN2/LOX/LH2/LAr), clean gas (air, N2, O2, CO2, natural gas, hydrogen, instrument air), and saturated and superheated steam, all single-phase and full-pipe, on DN50 to DN1200 pipe at PN0.6 to PN42 MPa and −200 to +800 °C. Sweet spot is noise-sensitive installs, high-pressure pressure-let-down service with measurement, and retrofits where upstream straight-pipe length is constrained. Out of scope: slurry and particulate-laden flow (holes plug; quote EMF or Coriolis), high-viscosity oil above 50 cSt (Reynolds correction grows; quote Coriolis or oval-gear PD), pulsating flow without an accumulator (square-root extraction amplifies error; quote Coriolis), wet-gas and two-phase service (quote Coriolis), and turndown requirements above 1:10 (DP physics caps turndown; quote vortex, ultrasonic, or Coriolis).
What ships with the meter and what is the lead time?+
Lead time is 5 to 7 business days from the factory. The element ships with the multi-hole disc machined to the sized β, an ISO 5167 / GB/T 2624 wet-flow calibration certificate from the factory loop, an ISO 9001 quality certificate, a mill cert traceable to the heat number on the wetted-metal grade ordered, and a tag plate stamped with the model code, β, pipe schedule, and design ΔP. Flanged builds ship in matched flange pairs per HG/T 20592 or ANSI 150/300/600/900/1500 lb per order. The integrated build adds a pre-mounted DP transmitter on a 3-valve manifold, factory-zeroed against the sized URL. EMC 2014/30/EU Annex II compliance ships with the integrated build. Sanitary, FDA, EHEDG, and USP elastomer certifications are not in scope for DP primary elements; if the service is sanitary, quote a Coriolis or a sanitary-fit EMF.

Need help sizing the multi-hole orifice plate build?

Send pipe DN, schedule, flowing P and T, fluid, and min/normal/max flow. Engineering returns a sized β, ΔP-transmitter URL, expected accuracy, and ship window within one business day; lead time 5–7 business days from the factory.