Integral Orifice Flow Meter
Factory-Mated Primary + DP Transmitter
DN15-DN1500 · PN0.6-PN42 MPa · ±0.5 % of flow
4-20 mA HART · IP65 · Ex d IIC T6 Gb optional
ISO 5167 / GB/T 2624 wet-cal · 5–7 business days
- One-PO sourcing for small-bore process gas, steam sub-measurement, batch chemical dosing, and OEM skid integration
- Primary element + DP transmitter + 3-valve manifold pre-assembled with factory K-factor and zero/span
- If you already run Rosemount 3051 / Yokogawa EJA / Honeywell ST3000 on plant, go to the bare orifice plate instead
Primary + 3-valve manifold + DP transmitter, factory-mated
Single packing slip · one warranty point · zero field zero-cal
The integral orifice flow meter (also called an integrated DP flow meter) is the factory-mated build of the differential-pressure series; primary element, DP transmitter, 3-valve manifold, and impulse tubing ship pre-assembled on one packing slip. DN15 to DN1500, PN42 MPa, ±0.5 % of flow per ISO 5167 / GB/T 2624 wet-cal. Factory sets the K-factor and zero/span before shipment: pipe it in, energize the 4-20 mA HART loop, and read flow. Lead time 5–7 business days.
Benefits
- Single-PO sourcing: primary, transmitter, manifold, and tubing on one packing slip with one warranty point of contact.
- Factory K-factor + zero/span: wet-flow cal on the loop before shipment removes four to eight hours of field commissioning per loop.
- ±0.5 % of flow per ISO 5167 / GB/T 2624: primary-element wet-cal accuracy on the standard custody and billing practice recognises.
- DN15 to DN1500 size span: small-bore process-gas branches up to mid-size steam sub-meters and packaged OEM skids.
- PN0.6 to PN42 MPa pressure range: low-pressure branches through high-pressure steam mains and hydrocarbon service.
- 4-20 mA HART loop-powered transmitter: 24 VDC two-wire, IP65, Ex d IIC T6 Gb optional, RS-485 Modbus optional.
- Lead time 5–7 business days from the factory.
Configure your build.
Pick line size, pressure rating, wetted material, connection style, transmitter output, and manifold style. The configurator returns the model code and a ballpark unit price; engineering replies with a sized quote within one business day.
Your Configuration
✓ ISO 5167 wet-cal + factory zero/span
✓ Reply within 4 business hours
Typical applications
Four applications where one-PO sourcing and factory zero/span beat the bare-primary route.
Small-bore process gas
Instrument air, nitrogen blanket, or fuel-gas branch on a DN25-DN100 line where adding one DP loop does not justify a Rosemount transmitter parts shelf and a trained DP technician.
Steam sub-measurement for utilities billing
Boiler-house steam header to building or process unit; 5-valve manifold and seal pots ship in the build so condensate columns and blow-down are commissioning-ready on day one.
Batch chemical dosing
Reactor or blending-line dose loop where the factory K-factor and ISO 5167 wet-cal give the batch record a traceable accuracy spec without standing up a transmitter calibration cart.
OEM packaged-skid integration
Steam-injection, fuel-gas conditioning, or chemical-dosing skid where footprint, single-vendor sourcing, and one warranty point matter more than transmitter-head flexibility.
Specifications
| Measurement principle | Differential-pressure (DP) primary element; orifice plate creates a permanent ΔP that scales with the square of volumetric flow. The factory-paired DP transmitter reads ΔP via impulse lines and outputs 4-20 mA HART proportional to flow after square-root extraction. |
|---|---|
| Reference standard | ISO 5167 (orifice flow measurement) and GB/T 2624 (China adoption of ISO 5167) |
| Accuracy | ±0.5 % of flow (primary-element wet-flow calibration); system accuracy also depends on transmitter URL and ISO 5167 conformance of the install |
| Repeatability | ±0.1 % typical, per ISO 5167 conformant install |
| Line sizes | DN15 to DN1500 (element 06 size range; larger bores go to the bare orifice plate element) |
| Working pressure | PN0.6 / PN1.0 / PN1.6 / PN2.5 / PN4.0 / PN6.4 / PN10 / PN16 / PN25 / PN42 MPa |
| Medium temperature | -200 to +800 °C (cryogenic LN₂ / LOX / LH₂ through superheated steam) |
| Beta ratio | 0.20 to 0.75 per ISO 5167; factory-sized per the operating P, T, and min/normal/max flow specified at quote |
| Turndown | 1:3 standard 4-20 mA loop; 1:7 to 1:10 with HART smart transmitter and multiple URL ranges |
| Tap geometry | Corner taps, D and D/2 taps, or flange taps per ISO 5167-2; flange taps standard for DN50-DN600 |
| Wetted materials | 304 SS, 316 SS, 316L SS, 321 SS, 12CrMo (chrome-moly), Cr5Mo, Hastelloy, Monel, Titanium (options per quote) |
| Connection | Flange HG/T 20592 PN0.6-PN42 MPa; ANSI 150 / 300 / 600 lb; NPT thread for DN15-DN50 small-bore service |
| DP transmitter (factory-paired) | 24 VDC loop-powered, 2-wire, 4-20 mA HART standard; RS-485 Modbus RTU optional; URL configurable 0-25 kPa / 0-100 kPa / 0-250 kPa / 0-1000 kPa |
| Manifold | 3-valve manifold standard (isolation + equalizing); 5-valve manifold optional for steam blow-down and seal-pot draining |
| Impulse tubing | 8-12 mm OD stainless tubing, factory-piped short-run to transmitter; field-extendable up to 5 m |
| Ambient temperature | -40 to +85 °C standard housing; -40 to +75 °C with Ex d IIC T6 Gb option |
| Hazardous-area cert | CNEX Ex d IIC T6 Gb (flameproof, Zone 1) on transmitter housing, optional |
| Ingress protection | IP65 standard; IP66 or IP67 by special order |
| Applicable media | Clean liquid (water, glycol, hydrocarbon, refined oil, cryogenic LN₂ / LOX / LH₂ / LNG), clean and dry gas (air, N₂, O₂, CO₂, natural gas, instrument air), saturated and superheated steam; single-phase, full-pipe |
| Not applicable to | Slurry, particulate-laden flow, two-phase or wet-gas service, pulsating flow without accumulator, very-low-flow service below the transmitter noise floor (go to ultrasonic, Coriolis, vortex, or EMF per the application) |
| Calibration | ISO 9001 wet-flow calibration on factory loop; factory K-factor and zero/span set before shipment; cert traceable to national flow standard |
| Certification ships standard | ISO 5167 / GB/T 2624 wet-cal certificate, ISO 9001 quality cert, mill cert traceable to heat number for wetted-metal element, EMC 2014/30/EU Annex II for the transmitter, CNEX Ex d IIC T6 Gb cert sheet when ordered |
| Lead time | 5–7 business days from factory |
Installation
Five rules for clean DP measurement on a factory-mated assembly.
- Honor the upstream straight-pipe length Allow 22D upstream of a single elbow at β = 0.5, 44D at β = 0.75; 5D downstream. Two elbows in plane need 30D; out of plane need 50D. Reducers and valves need 16D-18D. Use a flow conditioner if the pipework cannot deliver the required run.
- Mount horizontal; slope impulse tubing downward for steam Horizontal suits liquid and gas, transmitter above the pipe for gas or below for liquid. For steam, mount horizontally and slope impulse tubing 1:10 downward so seal-pot condensate columns form symmetrically. Mark flow direction before bolting up.
- Open isolation valves, close the equalizer, then power the loop The 3-valve manifold ships with isolation valves closed and the equalizing valve open. After install, open both isolation valves slowly, close the equalizing valve, then energize the 24 VDC loop. Factory zero/span holds.
- Bleed impulse lines before reading flow For liquid service, vent high-side and low-side from the top until clean stream runs; trapped air shifts ΔP by tens of kPa. For gas service, drain condensate from the low points. For steam, fill seal-pot columns with cool condensate before energizing.
- Route 4-20 mA HART wiring separate from VFD and motor cables Keep signal wiring at least 300 mm from motor-drive cables to avoid induced noise on the loop; shield grounded at the DCS / PLC end only. For Ex d IIC T6 Gb installs, follow the local Zone 1 code for cable-gland and conduit sealing.
Frequently asked questions
Need a one-PO DP flow meter for a small-bore or OEM-skid loop?
Send line size, operating P and T, fluid, and min/normal/max flow. Engineering returns a sized beta and a quote within one business day; lead time 5–7 business days from the factory.