Flanged Vortex Flow Meter
Flanged Vortex Standard Build
Accuracy of ±0.5% VRd
Temperature service −45 to +500 °C
Turndown ratio of 1:70
- Line sizes DN25 to DN400
- Flange ratings PN16 to PN160 (ANSI 150 to 2500 LB)
- Body materials 316L stainless or Hastelloy C

The Flanged Vortex Flow Meter is the standard LUGB build for steam, gas, and low-viscosity liquid service across DN25 to DN400 lines. Built-in T+P compensation outputs mass flow directly in kg/h.
316L stainless wetted parts cover most service. Hastelloy C is the upgrade for chloride, acid, or oxidising carry-over. CNEX Ex d IIC T6 Gb available on every configuration.
Benefits
- VRd accuracy: LUGB-VRd ±0.5 %, 1:70 turndown; 2024 China Instrument Society Top-10 New Product.
- Built-in T+P compensation: integrated RTD + pressure transducer feed the on-board flow computer, outputting mass flow or Nm³/h directly; no external multivariable transmitter.
- Pressure class: PN16–PN160 (ANSI 150–900 LB); 4× the wafer ceiling on the same bluff-body geometry.
- Temperature range: T0–T4 codes cover up to 500 °C; T5 cryogenic option extends down to −190 °C on the same family.
- Calibration curve: PN16–PN160 share one bluff body, so a DN100 calibration cert applies across the full pressure-class range.
- Hazardous-area certification: CNEX Ex d IIC T6 Gb (flameproof, Zone 1, gas group IIC) optional.
- Lead time: 5–7 business days from factory on every configuration.
Wafer vs flanged vs high-T; pressure & temperature comparison
| Service zone | Typical pressure | Typical medium T | Recommended body | Typical use |
|---|---|---|---|---|
| Utility | ≤ PN40 | ≤ 250 °C | Wafer (LUGB-W) | HVAC chilled water, LP steam sub-meter, process water |
| Saturated & process | PN40 – PN100 (H4–H10) | T1–T3: up to 400 °C | Flanged (LUGB) | Saturated main-header steam, petrochem process gas, refinery fuel gas |
| High-T superheat | PN40 – PN160 (H4–H16) | up to 500 °C (T4 code) | Flanged (LUGB) · VRd | Superheated main-header steam, process tie-in skids |
Configure your build.
Your Configuration
Flow range by pipe size.
Mass values are for saturated steam at 160 °C / 0.5 MPa (3.26 kg/m³). Volume values apply across gas service. Send your medium, line pressure, and operating temperature on the quote; the engineering team sizes the exact DN with the K-factor curve.
| DN | Inches | Velocity (m/s) | Gas volume (m³/h) | Saturated steam mass (kg/h) |
|---|---|---|---|---|
| DN25 | 1″ | 4 – 60 | 6 – 100 | 20 – 326 |
| DN32 | 1-1/4″ | 3 – 70 | 9 – 180 | 29 – 587 |
| DN40 | 1-1/2″ | 3 – 70 | 14 – 280 | 46 – 913 |
| DN50 | 2″ | 3 – 70 | 20 – 400 | 65 – 1,304 |
| DN65 | 2-1/2″ | 3 – 70 | 35 – 700 | 114 – 2,282 |
| DN80 | 3″ | 3 – 70 | 60 – 1,200 | 180 – 3,912 |
| DN100 | 4″ | 3 – 70 | 90 – 2,000 | 294 – 6,520 |
| DN125 | 5″ | 3 – 70 | 120 – 2,400 | 391 – 7,824 |
| DN150 | 6″ | 3 – 70 | 200 – 5,000 | 652 – 16,300 |
| DN200 | 8″ | 3 – 70 | 350 – 8,000 | 1,141 – 26,080 |
| DN250 | 10″ | 3 – 70 | 550 – 11,000 | 1,793 – 35,860 |
| DN300 | 12″ | 3 – 70 | 800 – 18,000 | 2,608 – 58,680 |
| DN350 | 14″ | 3 – 70 | 1,100 – 24,000 | 3,586 – 78,240 |
| DN400 | 16″ | 3 – 70 | 1,400 – 31,000 | 4,564 – 101,060 |
Specifications
Performance
Body & Range
A1 – A9: ANSI 150 / 300 / 600 / 900 LB
Materials & Flange standards
Electronics & Compliance
Where the flanged build is the standard choice
All four zones sit above PN40 or 250 °C; the wafer ceiling.
Power-plant auxiliary steam headers
Auxiliary steam at 4–6 MPa, 400–500 °C; flanged LUGB sits on balance-of-plant ahead of the deaerator.
Up to 500 °C · PN40–PN160Petrochemical process & refinery fuel gas
Process/fuel-gas headers up to 350 °C in CNEX hazardous zones; PN63–PN100.
Up to 350 °C · PN63-PN100Hot-oil & thermal-fluid loops
Heat-transfer fluid up to 400 °C, 1–4 MPa; hydrocarbon, battery-electrode drying, asphalt loops.
Up to 400 °CLPG vapor & cryogenic distribution
Cryogenic LUGB: −190 °C to +60 °C for liquid-N₂ and low-temperature gas/liquid lines.
Cryogenic · -190 °C to +60 °CFlange-side commissioning checklist
High-PN flanged service is unforgiving of bolt-torque errors and gasket-material mismatch. The six rules below cover the LUGB install sequence.
- Match the flange standard on both sides Confirm upstream and downstream pipe flanges match the meter’s flange standard and rating exactly.
- 10D upstream / 5D downstream straight run (LUGB install requirement) Vortex meters need 10 pipe diameters of undisturbed straight run upstream and 5D downstream as a LUGB install requirement.
- Use suitable gaskets for high-PN service On PN100 and PN160, use spiral-wound 316L / graphite or kammprofile gaskets; never sheet gaskets.
- Cross-pattern torque & second-pass re-torque Apply bolt torque in a cross-pattern in three progressive passes (30% → 60% → 100% target torque).
- Insulate the body; not the electronics head Wrap insulation up to the transmitter stem but leave the electronics head exposed.
- Verify T+P compensation at cold commissioning Before bringing the line to service temperature, use the HART interface to confirm the T+P module is reading pipe ambient correctly.
Frequently asked questions
When should I pick the flanged vortex flow meter over the wafer version?
What accuracy and turndown do I get on the flanged body?
How does the built-in T+P compensation work?
Do you support cryogenic service on the flanged body?
Which hazardous-area certifications do you ship?
What lead time on high-PN flanged builds?
Which DN should I pick for a flanged vortex flow meter; DN50 or DN100?
Need help sizing the flanged build?
Send per-tag line list; DN, PN/Class, medium T, area class, output. Model codes + pricing in 4 hours. 5–7 days lead time.