Clamp-on Ultrasonic Flow Meter
Non-Invasive Transit-Time Retrofit, DN15 – DN6000
DN15 to DN6000 via S/M/L transducer pair
±0.5 % of rate · 0 to ±32 m/s bi-directional
V / Z / N / W mounting modes for any host pipe
- No pipe cut, no shutdown, no civil works; retrofit measurement on the longest available straight run
- Host pipe range: steel, stainless, cast iron, copper, PVC, HDPE, PE, GRP, cement-lined
- Single-channel standard; 2 / 3 / 5-channel large-bore custody-grade option
The Clamp-on Ultrasonic Flow Meter measures liquid flow by sound transit-time between transducers clamped outside the host pipe; no pipe-cut, no shutdown. Patented multi-pulse balanced TX/RX resolves 40 ps; ±0.5 % of rate across DN10 to DN1000, ±1.0 % to DN6000. Three transducer pairs (S/M/L) cover DN15-DN6000; four mounting modes (V/Z/N/W). Outputs: 4-20 mA × 2, Modbus RTU, CAN, pulse OCT, HART option. AC 220 V or DC 8-36 V; UPS-72 backup. 5–7 business days from the factory.
Benefits
- Non-invasive clamp-on install; no pipe cut, no shutdown, no civil works. Transducer pair mounts external with coupling gel + stainless straps. 1 to 3 hours per meter.
- DN15 to DN6000 single-Series coverage; three transducer pairs (S / M / L) span the full bore range. No family change as pipe size scales.
- 40 ps time-difference resolution, ±0.5 % of rate. Patented multi-pulse balanced TX/RX.
- Four mounting modes (V / Z / N / W); V default; Z large-bore single-transit; N multi-bounce for adverse signal; W close-coupled below 50 mm.
- Bi-directional 0 to ±32 m/s; native reverse-flow detection with dual totalizers; fits return mains and reversible utility service.
- Multi-channel option (2 / 3 / 5-channel); for large-bore custody-grade or profile-asymmetric installs. Channel-pair redundancy supports SIF metering.
- 5–7 business days factory-direct; ISO 9001 cal cert, EMC 2014/30/EU, IP65 transmitter, transducer pair + gel kit + straps included.
Configure your build.
Build a quotable model code from transducer pair, mounting mode, output, power, and channel count. Send the configured code with your host pipe size, material, and flow target; the engineering team replies with a sized quote and unit price within one business day.
Your configuration
Mounting mode decision guide
Four mounting modes cover the full installation-condition range. The engineering team confirms the right mode based on host pipe size, material, and operating conditions at quote stage.
| Mode | When to use | Pipe size | Signal-path characteristic |
|---|---|---|---|
| V (default) | Standard mounting on common host pipes (steel, stainless, PVC, copper) | All DN | Single bounce off opposite pipe wall; transducer spacing per the spacing table |
| Z | Large-bore service, smooth host-pipe interior, clean signal | DN100 – DN6000 | Single transit through pipe; transducer pair on opposite sides, ~200 mm spacing |
| N | Adverse signal quality; degraded outer pipe surface, scaled inner wall, signal attenuation | All DN | Multi-reflection path; wider transducer spacing; multiple bounces stretch signal |
| W | Small-bore service, weak-signal pipe material, close-coupled transducer pair | Below DN50 | Close-coupled multi-bounce path through small pipe diameter |
Applications
HVAC chilled-water + condenser sub-measurement
Building energy audit (LEED v4, ISO 50001), chiller-plant primary, CRAH branches, district-cooling headers. Non-invasive retrofit on 4-12 inch mains without shutdown.
District-heating primary + secondary
City-side substations, building entry meters, bi-directional return-line metering. BTU calorific via temperature-pair pairing; integrates with Kamstrup / Diehl / Itron via Modbus.
Data-center liquid cooling + utility audit
Primary cooling loop, CDU + CRAH branches, PUE/TUE reporting, tenant chargeback. Multi-channel for large-diameter mains where single-channel drifts on profile asymmetry.
Industrial process water + utility retrofit
Cooling-tower makeup, boiler condensate, DI/RO water (below EMF threshold), cast-iron / GRP / HDPE mains retrofit. ≤10 000 ppm particulate.
Full specifications.
| Measurement principle | Transit-time ultrasonic, multi-pulse balanced TX/RX, 40 ps time-difference resolution |
|---|---|
| Pipe diameter range | DN15 to DN6000 via S / M / L transducer pair |
| Nominal diameter | Clamp-on external mount; the meter itself has no process port; the host pipe DN is the measured diameter (see Pipe diameter range row above) |
| Transducer pair | S (DN15-DN100) · M (DN50-DN700) · L (DN300-DN6000) |
| Mounting modes | V (default) · Z (large-bore) · N (multi-bounce) · W (small-bore) |
| Accuracy | ±0.5 % of rate (DN10-DN1000) · ±1.0 % large-bore |
| Repeatability | 0.2 % of span |
| Velocity range | 0 to ±32 m/s, bi-directional with reverse-flow detection |
| Channel count | Single (standard) · 2 / 3 / 5-channel optional |
| Pipe materials supported | Steel · stainless · ductile iron · cast iron · copper · PVC · PE · HDPE · GRP · concrete-lined (acoustic-coupling treatment may be required for cement-lined or scale-coated) |
| Particulate tolerance | ≤ 10 000 ppm suspended solids |
| Medium temperature | −10 °C to +150 °C (transducer dependent) |
| Process temperature | −30 °C to +150 °C |
| Ambient temperature | −10 °C to +70 °C operating · −30 °C to +150 °C storage |
| Output signals | 4-20 mA × 2 (0.1 % accuracy) · 4-20 mA / 0-20 mA / 0-1 kΩ analogue · Pulse 1-9999 Hz OCT · OCT alarm × 2 · RS-232 · RS-485 Modbus RTU · CAN bus · HART optional |
| Display | 4-line LCD with 4×4 keypad, 500 ms update rate |
| Logging | Daily totalizer + scheduled-interval point log; 32-meter multi-instrument addressing |
| Cable | SEYV75-2 transducer cable, up to 500 m sensor-to-converter |
| Power supply | AC 220 V · DC 8-36 V · AC 7-30 V (factory-selectable at order) |
| Backup power | UPS-72 option (72-hour battery on AC 220 V mains) |
| Power consumption | 2 W typical |
| Ingress protection | IP65 fixed-mount transmitter |
| Hazardous area | Ex d available as factory custom build (NOT a standard option) |
| Dimensions | Transmitter 251 × 192 × 80 mm (W × D × H); transducer S/M/L per the sizing table |
| Weight | Transmitter 3 kg fixed-mount · 1.5 kg portable version |
| Compliance | EMC 2014/30/EU (Annex II) · ISO 9001 calibration certificate with each meter |
| Lead time | 5 to 7 business days from factory |
Installation rules.
- Respect 10D upstream / 5D downstream / 30D after pump. Mount on the longest available straight run.
- Verify pipe-fill before measurement. Pipe must stay 100 % liquid-filled; air pockets falsify the signal. Mount horizontal or vertical-upward.
- Prep the host-pipe outer surface. Remove paint, rust, scale, and insulation at the transducer footprint. Apply coupling gel; secure transducer pair with stainless straps at the specified spacing.
- Re-apply coupling gel every 6 to 12 months in outdoor service. UV, temperature cycles, and moisture degrade the gel; indoor service extends life beyond 12 months.
- Run SEYV75-2 sensor cable on a separate path from power cables (300 mm minimum). Up to 500 m sensor-to-converter; longer runs need a signal repeater.
Frequently asked questions
Need help spec’ing the build?
Send host pipe DN and material, medium, flow target, and output preference. Engineering replies with transducer pair, mounting mode, and quote in one business day.